Print Back

Features/Applications

The following switch is a hand operated, control circuit device, rated ‘Heavy Duty’ normally for use with electromagnetic equipment.  The body and wing lever is made from die-cast zinc and painted with a dry powder paint.    

 

Each captive terminal will accept (2) #14 AWG stranded wires.  Each switch is supplied with all mounting hardware and a solid santoprene rubber gasket which provides an oil tight seal upon installation.  The mechanical life of this device is 500,000 operations. 

 

This switch can be found on a variety of machinery.  Its rugged construction and long term reliability make this switch extremely well suited to function within various industrial conditions.

 

Electrical Ratings

“HEAVY DUTY – A600 / N300”

Listed under UL 508 – File # E 58589

Certified under CSA C22.2 – File # LR 3648
CE Compliant EN 60947-5-1

 

Environmental Temperature Range

Operating:  +32oF to +131oF (0oC to +55oC)

Storage:  -40oF to +185oF (-40oC to +85oC)

Note:  Operating temperatures at 0oC are based on the absence of freezing moisture and liquids.

 

Normal Potential

Normal Current

Inrush Current

110-120 aca volts

6.0 amp.

60.0 amp.

220-240 aca

3.0 amp.

30.0 amp.

440-480 aca

1.5 amp.

15.0 amp.

550-600 aca

1.2 amp.

12.0 amp.

115-125 dcb

2.2 amp.

-----

230-250 dcb

1.1 amp.

-----

a  Power factor 0.35 or less

b  Inductive loads as specified in Section 125 of Industrial

   Control Devices, Controllers and Assemblies, ANSI /

   NEMA ICS 2-1988

WARNING - DANGER

These products should only be used where point-of-operation guarding devices have been properly installed & maintained so that appropriate OSHA and ANSI B11.1 regulations & standards are met.  Misapplication of the products on machinery lacking effective point-of operation safeguards can cause serious injury to the operator of that machinery.

---------------------------------------------------------------------------------------------------------------------

AVERTISSMENT - DANGER

Ces produit doivent seulement être utilisés sur des postes à risque correctement sécurisés et entretenus afin d’être conforme aux standards et régulations en vigueur (CSA, CLC). Un mauvais usage de ces produits sur des machines et des postes de travail non sécurisés de manière efficace peut causer des blessures graves au technicien maniant ces machines.

Unit of Measure

Specifications

Wing Lever Color

N/A Black

Body Color

N/A Black

Lockable Latch

N/A No

Special Features

N/A None

Contact Arrangement (All Maintained)

N/A #65 - 2 Pos./ 2 Poles,
Maintained

Approx. Shipping Weight

N/A 1.35 lb

Old Catalog Number

N/A 3496