This switch is a slack cable style with 1 NO and 1 NC momentary “Slow-Make – Slow Break” contacts.  This switch also has “Positive Break” contacts and may be used as an emergency stop switch.

 

This low activating force switch is basically a pushbutton device operated through a nickel plated operating lever attached to the cover.  Care must be taken when choosing and installing the operating rope because the low operating force can be easily overcome and the switch will not trip or reset properly.

 

This switch requires a suitable enclosure which must be purchased separately.  One enclosure suggestion is Rees number 02765-000.  A sealing gasket and four mounting screws are supplied with each switch.

 

Each captive terminal will accept (2) #14 AWG stranded wires.

 

·        Low operating force

·        Gold plated contacts eliminate high resistance tarnishing

·        Positive Break contacts      

·        Nema 12/13, IP 65

                                                                       

The maximum recommended rope length is 33 feet with a maximum interval support of 10 feet when horizontal.

 

The mechanical life of the switch is in excess of 1,000,000 operations.

 

Electrical Ratings

“HEAVY DUTY – A600 / N300”

Listed under UL 508 – File # E 58589

Certified under CSA C22.2 – File # LR 3648

CE Compliant IEC/EN 60947-5-1

 

Environmental Temperature Range

Operating:  +32oF to +131oF (0oC to +55oC)

Storage:  -40oF to +185oF (-40oC to +85oC)

Note:  Operating temperatures at 0oC are based on the absence of freezing moisture and liquids.

 

Normal Potential

Normal Current

Inrush Current

110-120 aca volts

6.0 amp.

60.0 amp.

220-240 aca

3.0 amp.

30.0 amp.

440-480 aca

1.5 amp.

15.0 amp.

550-600 aca

1.2 amp.

12.0 amp.

115-125 dcb

2.2 amp.

-----

230-250 dcb

1.1 amp.

-----

a  Power factor 0.35 or less

b  Inductive loads as specified in Section 125 of Industrial

   Control Devices, Controllers and Assemblies, ANSI /

   NEMA ICS 2-1988

 

WARNING - DANGER

These products should only be used where point-of-operation guarding devices have been properly installed & maintained so that appropriate OSHA and ANSI B11.1 regulations & standards are met.  Misapplication of the products on machinery lacking effective point-of operation safeguards can cause serious injury to the operator of that machinery.

---------------------------------------------------------------------------------------------------------------------

AVERTISSMENT - DANGER

Ces produit doivent seulement être utilisés sur des postes à risque correctement sécurisés et entretenus afin d’être conforme aux standards et régulations en vigueur (CSA, CLC). Un mauvais usage de ces produits sur des machines et des postes de travail non sécurisés de manière efficace peut causer des blessures graves au technicien maniant ces machines.

Unit of Measure

Specifications

Trip Force

N/A 6 lb

Operating Force Between 10 ft. Supports

N/A 0.7 lb

Operating Type

N/A Momentary Slow Make/Slow Break

Contact Arrangement

N/A #9 NO + NC

Old Catalog Number

N/A 3275