Print Back

Features/Applications

This inline cable switch utilizes a slack cable style with “Slow-Make – Slow Break” contacts.  This switch does NOT provide “Positive Break” or “Positive Transfer” features and should only be used for non-emergency, normal start – stop applications.

This momentary switch is assembled with one normally open contact which is held open by a spring in the switch body.  Pulling of the ring eye collapses the spring, allowing the contact to close and actuate the circuit it is connected to.  Releasing of the rope then allows the spring to expand thereby opening the contact.

The housing is made from high quality yellow nylon. It is intended to hang in-line with the cable run or directly from an eye bolt.

  • 10lb Trip Force
  • Gold plated contacts eliminate high resistance tarnishing
  • Nema Type 4 Indoor Only, IP 65
  • UL Listed (File E58589); C-UL-US

The switch comes pre-wired for quick and easy installation and utilizes a 5 pin M12 connector.  The maximum cable recommended cable length is 33 feet in each direction with a maximum interval support of 10 feet.

The mechanical life of the switch is 100,000 operations.

The rugged construction and long term reliability makes this cable pull switch well suited to function within various environments.

There are many configurations available for the 04963-XXX series switches. Please contact us for more information if you do not see a fit for your application.

Electrical Ratings

60V, 4A Max.

UL Listed (File E58589); C-UL-US;

Switches comply with UL-508; CSA-C 22.2 No. 14; EN 60947-5-1:2017

Environmental Temperature Range

Operating:  +32oF to +131oF (0oC to +55oC)

Storage:  -40oF to +185oF (-40oC to +85oC)

Note:  Operating temperatures at 0oC are based on the absence of freezing moisture and liquids.

WARNING - DANGER

These products should only be used where point-of-operation guarding devices have been properly installed & maintained so that appropriate OSHA and ANSI B11.1 regulations & standards are met.  Misapplication of the products on machinery lacking effective point-of operation safeguards can cause serious injury to the operator of that machinery.

---------------------------------------------------------------------------------------------------------------------

AVERTISSMENT - DANGER

Ces produit doivent seulement être utilisés sur des postes à risque correctement sécurisés et entretenus afin d’être conforme aux standards et régulations en vigueur (CSA, CLC). Un mauvais usage de ces produits sur des machines et des postes de travail non sécurisés de manière efficace peut causer des blessures graves au technicien maniant ces machines.

Unit of Measure

Specifications

Trip Force

N/A 10 lb

Operating Force Between 10 ft. Supports

N/A 1.2 lb

Connector

N/A 5 pin M12 connector

Indicator Light

N/A N/A

Contact Arrangement

N/A 1 NO momentary