Features/Applications

Available in Lockable, Push-Pull, and Momentary versions, the following switches are hand operated, control circuit devices, rated ‘Heavy Duty’ normally for use with electromagnetic equipment.  The body is made from die-cast zinc.  The mushroom shaped plungers are molded from DuPont Delrin 100ST Acetal for improved impact resistance and are solid colors throughout.

 

  • UL/NISD E357870
  • Nema 12/13, IP 65
  • Gold Plated Contacts

Each operator will accept up to three tiers of two contact blocks for a total of six separate blocks.  Each operator is supplied with all mounting hardware and a Buna-N (NBR) o-ring which provides an oil tight seal upon installation.  The mechanical life of these units is 1,000,000 operations. 

 

These devices can be found on a variety of machinery, used to perform such operations as ‘start’, ‘stop’, ‘top stop’, ‘inch’, ‘jog’, ‘on’, ‘off’, ‘forward’, ‘reverse’, etc.

 

The 22102 series satisfies the requirements of IEC 60947-5-5 – 3.9 direct opening action (positive opening action) (of a contact element); when one or more of any of our normally closed contact blocks are fitted on any red operator.  This is commonly referred to as “Positive Break”, meaning the breaking of the normally closed contact(s) is not dependent upon springs.

 

Electrical Ratings

“HEAVY DUTY – A600 / N150”

 

Environmental Temperature Range

Operating:  +32oF to +131oF (0oC to +55oC)

Storage:  -40oF to +185oF (-40oC to +85oC)

Note:  Operating temperatures at 0oC are based on the absence of freezing moisture and liquids.

 

Normal Potential

Normal Current

Inrush Current

110-120 aca volts

6.0 amp.

60.0 amp.

220-240 aca

3.0 amp.

30.0 amp.

440-480 aca

1.5 amp.

15.0 amp.

550-600 aca

1.2 amp.

12.0 amp.

115-125 dcb

2.2 amp.

-----

230-250 dcb

1.1 amp.

-----

a  Power factor 0.35 or less

b  Inductive loads as specified in Section 125 of Industrial

   Control Devices, Controllers and Assemblies, ANSI /

   NEMA ICS 2-1988

WARNING - DANGER

These products should only be used where point-of-operation guarding devices have been properly installed & maintained so that appropriate OSHA and ANSI B11.1 regulations & standards are met.  Misapplication of the products on machinery lacking effective point-of operation safeguards can cause serious injury to the operator of that machinery.

---------------------------------------------------------------------------------------------------------------------

AVERTISSMENT - DANGER

Ces produit doivent seulement être utilisés sur des postes à risque correctement sécurisés et entretenus afin d’être conforme aux standards et régulations en vigueur (CSA, CLC). Un mauvais usage de ces produits sur des machines et des postes de travail non sécurisés de manière efficace peut causer des blessures graves au technicien maniant ces machines.

Specifications

Operator Color

N/A Red

Padlock Feature

N/A Yes

Switch Type

N/A Maintained
UL/NISD

Positive Opening Contact

N/A
 

Adapter Included

N/A No

Legend
Plate
Included

N/A No

Contact
Block(s)
Included