Features/Applications
This contact block is designed for use on ALL REES push button operators and selector switches. Each captive terminal on the contact block will accept (2) #14 AWG stranded wires.
Electrical Ratings
“HEAVY DUTY – A600 / N150”
Listed under UL 508 – File # E 58589
Certified under CSA C22.2 – File # LR 3648
CE Compliant IEC/EN 60947-5-1
Environmental Temperature Range
Operating:  +32oF to +131oF (0oC to +55oC)
Storage:  -40oF to +185oF (-40oC to +85oC)
Note:  Operating temperatures at 0oC are based on the absence of freezing moisture and liquids.
| Normal Potential | Normal Current | Inrush Current | 
| 110-120 aca volts | 6.0 amp. | 60.0 amp. | 
| 220-240 aca  | 3.0 amp. | 30.0 amp. | 
| 440-480 aca  | 1.5 amp. | 15.0 amp. | 
| 550-600 aca | 1.2 amp. | 12.0 amp. | 
| 115-125 dcb | 2.2 amp. | ----- | 
| 230-250 dcb | 1.1 amp. | ----- | 
a  Power factor 0.35 or less
b  Inductive loads as specified in Section 125 of Industrial
   Control Devices, Controllers and Assemblies, ANSI / 
   NEMA ICS 2-1988
| Item Photo | N/A
                                                                                          50703-000 | 
| Chrysler NPM Code | N/A - | 
| Adapter Included | N/A - | 
| Legend | N/A - | 
| Dimensional Drawing | N/A
                                                                                          Dimensional Drawing | 