Features/Applications
The following switch is a hand operated, control circuit device, rated ‘Heavy Duty’ normally for use with electromagnetic equipment. The body is made from die-cast zinc. The black mushroom style plastic plunger head is solid color throughout.
Each operator will accept up to three tiers of two contact blocks for a total of six separate circuits. Each operator is supplied with all mounting hardware and a solid neoprene rubber gasket which provides an oil tight seal upon installation. The mechanical life of this unit is 1,000,000 operations.
This device can be found on a variety of machinery, used to perform such operations as ‘start’, ‘stop’, ‘top stop’, ‘inch’, ‘on’, ‘off’, ‘forward’, ‘reverse’, etc.
Electrical Ratings
“HEAVY DUTY – A600 / N150”
Environmental Temperature Range
Operating: +32oF to +131oF (0oC to +55oC)
Storage: -40oF to +185oF (-40oC to +85oC)
Note: Operating temperatures at 0oC are based on the absence of freezing moisture and liquids.
Normal Potential
|
Normal Current
|
Inrush Current
|
110-120 aca volts
|
6.0 amp.
|
60.0 amp.
|
220-240 aca
|
3.0 amp.
|
30.0 amp.
|
440-480 aca
|
1.5 amp.
|
15.0 amp.
|
550-600 aca
|
1.2 amp.
|
12.0 amp.
|
115-125 dcb
|
2.2 amp.
|
-----
|
230-250 dcb
|
1.1 amp.
|
-----
|
a Power factor 0.35 or less
b Inductive loads as specified in Section 125 of Industrial
Control Devices, Controllers and Assemblies, ANSI /
NEMA ICS 2-1988
WARNING - DANGER
These products should only be used where point-of-operation guarding devices have been properly installed & maintained so that appropriate OSHA and ANSI B11.1 regulations & standards are met. Misapplication of the products on machinery lacking effective point-of operation safeguards can cause serious injury to the operator of that machinery.
---------------------------------------------------------------------------------------------------------------------
AVERTISSMENT - DANGER
Ces produit doivent seulement être utilisés sur des postes à risque correctement sécurisés et entretenus afin d’être conforme aux standards et régulations en vigueur (CSA, CLC). Un mauvais usage de ces produits sur des machines et des postes de travail non sécurisés de manière efficace peut causer des blessures graves au technicien maniant ces machines.